Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
2.
Braz J Otorhinolaryngol ; 89(1): 122-127, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34896035

RESUMO

OBJECTIVE: To assess the diagnostic agreement between smartphone-enabled otoscopy and rigid otoendoscopy in tympanic membrane and middle ear diseases. METHODS: A cross-sectional study was carried out to analyze otoscopies in patients seen at a general otorhinolaryngology (ORL) outpatient clinic, from June to December 2019. Eighty-three images of patients obtained from otoscopies performed through a smartphone device and a rigid endoscope were included, recorded, and stored for further analysis. The images were first analyzed by an experienced otologist, who assigned his diagnostic impression (defined as the gold standard) on each of the images. After this analysis, the images were displayed to a group of secondary raters (an experienced otorhinolaryngologist, a second-year resident in ORL, and a general practitioner). A questionnaire was applied related to each image. RESULTS: There was high agreement between the smartphone device and the otoendoscopy images for all professionals, with a Kappa coefficient of 0.97 (p < 0.001). The smartphone device showed a diagnostic sensitivity of 81.1% and a specificity of 71.1%. As for the otoendoscopy, it showed a sensitivity of 84.7% and a specificity of 72.4%. The image classification as "2 = Good" was the most frequent one, with 34.9% for otoendoscopy and 31.6% for the smartphone device. CONCLUSION: There was a high diagnostic agreement between smartphone device-guided otoscopy and the rigid otoendoscopy, demonstrating the feasibility of using this device in clinical practice.


Assuntos
Smartphone , Membrana Timpânica , Humanos , Otoscopia/métodos , Estudos Transversais , Membrana Timpânica/diagnóstico por imagem , Otorrinolaringologistas
3.
Braz. j. otorhinolaryngol. (Impr.) ; 89(1): 122-127, Jan.-Feb. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1420919

RESUMO

Abstract Objective: To assess the diagnostic agreement between smartphone-enabled otoscopy and rigid otoendoscopy in tympanic membrane and middle ear diseases. Methods: A cross-sectional study was carried out to analyze otoscopies in patients seen at a general otorhinolaryngology (ORL) outpatient clinic, from June to December 2019. Eighty-three images of patients obtained from otoscopies performed through a smartphone device and a rigid endoscope were included, recorded, and stored for further analysis. The images were first analyzed by an experienced otologist, who assigned his diagnostic impression (defined as the gold standard) on each of the images. After this analysis, the images were displayed to a group of secondary raters (an experienced otorhinolaryngologist, a second-year resident in ORL, and a general practitioner). A questionnaire was applied related to each image. Results: There was high agreement between the smartphone device and the otoendoscopy images for all professionals, with a Kappa coefficient of 0.97 (p < 0.001). The smartphone device showed a diagnostic sensitivity of 81.1% and a specificity of 71.1%. As for the otoendoscopy, it showed a sensitivity of 84.7% and a specificity of 72.4%. The image classification as "2 = Good" was the most frequent one, with 34.9% for otoendoscopy and 31.6% for the smartphone device. Conclusion: There was a high diagnostic agreement between smartphone device-guided otoscopy and the rigid otoendoscopy, demonstrating the feasibility of using this device in clinical practice. Level of Evidence: 3

4.
Braz. j. otorhinolaryngol. (Impr.) ; 88(supl.5): 108-111, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1420883

RESUMO

Abstract Objective: To analyze the anatomical relationship between the lacrimal sac and the agger nasi cell on Computed Tomography (CT); to correlate the right and left sides on each scan. Methods: CT scans of adult patients were reviewed for pneumatization of the agger nasi and its relationship to the lacrimal sac. The degree of agreement between the right and left sides was also evaluated. Results: A total of 130 CT scans were examined. An agger nasi cell was found medial to the lacrimal sac in 59.23% of scans. On 86.15% of scans, pneumatization was similar on both sides. Conclusion: The agger nasi air cell is located medial to the lacrimal sac in more than half of individuals. The right and left sides exhibit the same pneumatization pattern in approximately 80% of cases. Level of evidence: 4.

5.
Braz J Otorhinolaryngol ; 88 Suppl 5: S108-S111, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35331654

RESUMO

OBJECTIVE: To analyze the anatomical relationship between the lacrimal sac and the agger nasi cell on Computed Tomography (CT); to correlate the right and left sides on each scan. METHODS: CT scans of adult patients were reviewed for pneumatization of the agger nasi and its relationship to the lacrimal sac. The degree of agreement between the right and left sides was also evaluated. RESULTS: A total of 130 CT scans were examined. An agger nasi cell was found medial to the lacrimal sac in 59.23% of scans. On 86.15% of scans, pneumatization was similar on both sides. CONCLUSION: The agger nasi air cell is located medial to the lacrimal sac in more than half of individuals. The right and left sides exhibit the same pneumatization pattern in approximately 80% of cases.


Assuntos
Ducto Nasolacrimal , Adulto , Humanos , Ducto Nasolacrimal/diagnóstico por imagem , Seio Etmoidal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Nariz
6.
Int. arch. otorhinolaryngol. (Impr.) ; 23(1): 18-24, Jan.-Mar. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1002171

RESUMO

Abstract Introduction Low exposure of the larynx can make laryngeal microsurgery difficult or even impossible. The application of rigid and contact endoscopy enabled oblique and retrograde angled visualization, allowing transoperative staging with greater reach of the anatomical areas. However, there is difficulty or even impossibility of performing the surgical act, due to the incompatibility of the angled path with the straight surgical tools. Objective To demonstrate the efficiency of the variant of the technique for laryngeal microsurgery in cases of difficult laryngoscopy and to analyze the new surgical instruments specific to the endoscopic procedure. Methods This is a cross-sectional retrospective study, based on the analysis of 30 medical records of patients treated surgically at a philanthropic hospital in the state of Sergipe, Brazil, between the years of 2014 and 2015. Results The technical variant used 30- and 70-degree endoscopes that provided complete oblique view of the endolarynx. The association of angled instruments (forceps, suction pumps, retractors and scissors) enabled the execution of the surgical procedures. Conclusion The association of rigid endoscopy with angled instruments promoted full visualization of the surgical lesion and operative resolution. (AU)


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Laringoscopia/métodos , Microcirurgia/métodos , Brasil , Doenças da Laringe/cirurgia , Estudos Transversais , Estudos Retrospectivos , Laringoscopia/instrumentação
7.
Int Arch Otorhinolaryngol ; 23(1): 18-24, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30647779

RESUMO

Introduction Low exposure of the larynx can make laryngeal microsurgery difficult or even impossible. The application of rigid and contact endoscopy enabled oblique and retrograde angled visualization, allowing transoperative staging with greater reach of the anatomical areas. However, there is difficulty or even impossibility of performing the surgical act, due to the incompatibility of the angled path with the straight surgical tools. Objective To demonstrate the efficiency of the variant of the technique for laryngeal microsurgery in cases of difficult laryngoscopy and to analyze the new surgical instruments specific to the endoscopic procedure. Methods This is a cross-sectional retrospective study, based on the analysis of 30 medical records of patients treated surgically at a philanthropic hospital in the state of Sergipe, Brazil, between the years of 2014 and 2015. Results The technical variant used 30- and 70-degree endoscopes that provided complete oblique view of the endolarynx. The association of angled instruments (forceps, suction pumps, retractors and scissors) enabled the execution of the surgical procedures. Conclusion The association of rigid endoscopy with angled instruments promoted full visualization of the surgical lesion and operative resolution.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...